TVSS Signal Protection
|
|
|
| |
Your choices are...
|
|
|
| |
AC Single Phase
|
|
Configured to suppress surges, spike, transients, etc., on single phase AC power lines.
|
| |
AC Three Phase
|
|
Configured to suppress surges, spike, transients, etc., on three phase AC power lines.
|
| |
DC / Dataline
|
|
Configured to suppress surges, spike, transients, etc., on DC data, phone, and signal lines.
|
| |
Search Logic:
|
|
All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
|
 |
| |
Power Conditioner
|
|
Unit with full power conditioning capabilities, including functions such as voltage regulation in combination, output isolation, noise and spike attenuation, harmonic filtering, etc., to ensure the quality and consistency of power to sensitive medical, laboratory, computer, and other high technology equipment.
|
| |
Search Logic:
|
|
"Required" and "Must Not Have" criteria limit returned
matches as specified. Products with optional attributes
will be returned for either choice.
|
 |
| |
Outlets / Connections
|
|
|
| |
Your choices are...
|
|
|
| |
Electrical Outlets (AC)
|
|
Standard three-hole or other types of outlets.
|
| |
RJ11 / RJ13 / RJ14 Phone Jacks
|
|
Typically used for telecommunication lines, can be used for data lines as well.
|
| |
RJ41 / RJ45 / RJ48 Data Jacks
|
|
Typically used for data lines (Ethernet, LAN etc.).
|
| |
Coaxial Cable Connectors
|
|
Outlets can be BNC, SMA, UHF, or 7/16 DIN etc.
|
| |
Other
|
|
Other unlisted, specialized, or proprietary outlet types.
|
| |
Search Logic:
|
|
All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
|
 |

|

|
| |
|
|
|
| |
Your choices are...
|
|
|
| |
Wall / Panel / Backboard Mount
|
|
The unit can be mounted on a wall or backboard via bolting/mounting holes on the SPD.
|
| |
DIN Rail
|
|
Designed to mount onto DIN rail.
|
| |
Rack Mount
|
|
Mounts on or in rack
|
| |
Hard-Wired / Device Mount
|
|
The device physically mounts on or within the device to be protected from the surge.
|
| |
In-Line / Integrally Attached
|
|
The device is threaded or is meant to integrally attached to conduits, cabling etc.
|
| |
Plug-in Module
|
|
The unit is a module meant to plug into an existing system or surge protection device.
|
| |
PCB Mount
|
|
Wired or soldered onto Printed Circuit Boards.
|
| |
Search Logic:
|
|
All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
|
 |

|

|
| |
Maximum Surge Current:
|
|
Maximum current allowed for a single impulse waveform with continuous voltage applied. This level is used to indicate the protection capacity of a particular surge suppressor design, and when specifying a suppressor for a given application. For example, in a high exposure application with very large transients present from lightning, a higher-level surge current capacity would be required.
|
| |
Search Logic:
|
|
All matching products will have a value greater than or equal to the specified value.
|
 |
| |
AC Energy Absorption:
|
|
The measurement of a surge protective device's ability to absorb heat energy created by transient surges. Note that the Joule rating is not a part of IEEE or UL Standards.
|
| |
Search Logic:
|
|
All matching products will have a value greater than or equal to the specified value.
|
 |
| |
Maximum AC Power:
|
|
The maximum AC power that the unit can handle.
|
| |
Search Logic:
|
|
All matching products will have a value greater than or equal to the specified value.
|
 |
| |
DC Energy Absorption:
|
|
The measurement of a surge protective device's ability to absorb heat energy created by transient surges. Note that the Joule rating is not a part of IEEE or UL Standards.
|
| |
Search Logic:
|
|
All matching products will have a value greater than or equal to the specified value.
|
 |
| |
Maximum DC Power:
|
|
The maximum DC power that the unit can handle.
|
| |
Search Logic:
|
|
All matching products will have a value greater than or equal to the specified value.
|
 |

|

|
| |
|
|
|
| |
Your choices are...
|
|
|
| |
Hospital / Medical Grade
|
|
The SPD is approved and recognized by UL as Hospital Grade or otherwise rated for medical applicaiton. Hospital grade surge protective devices have to pass additional safety tests performed to measure leakage current.
|
| |
Self-Diagnostics
|
|
System is able to perform internal checks to ensure it is properly grounded, powered etc.
|
| |
Status Indicators / LEDs
|
|
LEDs can give an indication of Ground Tests, Surges, Faults etc.
|
| |
Resettable Circuit Breaker
|
|
The SPD can trip an internal breaker to protect the device against excessive surges. The SPD can be manually reset once corrective action has been taken.
|
| |
Audible Alarm
|
|
On occurrence of a surge, an audible alarm is activated.
|
| |
Sine Wave Tracking
|
|
Surges are attenuated and dissipated as part of a normal power sine wave.
|
| |
Surge Counter
|
|
A physical count of the number of surges handled by the device. Remote alarm contacts.
|
| |
Search Logic:
|
|
All products with ANY of the selected attributes will be returned as matches. Leaving all boxes unchecked will not limit the search criteria for this question; products with all attribute options will be returned as matches.
|
 |

|

|
| |
Operating Temperature:
|
|
Full required range of operating temperature.
|
| |
Search Logic:
|
|
User may specify either, both, or neither of the limits in a "From - To" range; when both are specified, matching products will cover entire range. Products returned as matches will meet all specified criteria.
|
 |
|